390/641 Bosch Rexroth AG | Tightening Technology 3 608 878 300
System 350 | 3 608 878 300/2019-03
MID 0062 Last tightening results data acknowledgement
MID 0063 Cancel last tightening results data
MID 0064 Archived tightening results upload request
MID 0065 Archived tightening results response
Sent by: superordinate computer
Last tightening results data acknowledgement
Note: -
Revision: 001(supported by Rexroth OP and Rexroth OPBMW)
Data field: is empty, 0 bytes
Possible response: none
Sent by: superordinate computer
Reset the subscription for the last tightening result.
Note: -
Revision: 001 (supported by Rexroth OP and Rexroth OP-Ford and Rexroth OP-BMW)
Data field: is empty, 0 bytes
Possible responses MID Error no. Comment
Command accepted 0005 –
Command error 0004 10 Activation for the last tightening result not available
Sent by: superordinate computer
A ring memory is implemented on the CF card that is used to store the tightening results. If there is no CF card in the
system when the OP is activated, the error message "Open Protocol: CF card for saving results not available!" (class
3) is generated.
When the OP is activated, each tightening result will be provided with a consecutive ID (beginning with 1). This
means that each new tightening result that is output while the OP is active will be provided with the next higher
unassigned number. However, this also means that tightening results that are output while the OP is deactivated will
not be stored. After the OP is reactivated, ID assignment will continue with the next higher number.
If the results file is deleted manually or the CF card is exchanged, storage will once again begin with ID 1.
Note: -
Revision: see MID 0065
Data field: Tightening ID, 10 bytes
Possible responses MID Error no. Comment
Archived tightening results response 0065 –
Command error 0004 15 Requested tightening ID not found
Sent by: Tightening controller
Upload the archived tightening.
Note: -
Revision: Number Supported by
001 Rexroth OP and Rexroth OP-Ford
002 Rexroth OP
003 Rexroth OP
004 Rexroth OP
004 Rexroth OP-BMW (corresponds to revision 001 Rexroth OP-
Ford)
Data field: Data 98 bytes (revision 001), 206 bytes (revision 002), 213 bytes (revision 003), 294 bytes (revision
004)