AFO default values
The AFO default values are defined as in the following table. The values can be changed and will be
accepted upon insertion of an AFO into the AFO table.
Table 6–143: AFO default values in the view configuration Rexroth IPM Protocol
Element Type Value range Standard value Comment
Graph filter List (expandable) – no graph
–only OK graph
– only NOK graph
– OK and NOK
graph
OK and NOK graph Determination for which results
the graphs are to be transmitted
Graph data List (expandable) – Angle
– Torque
–Gradient
– Redundancy
torque
– Redundancy
angle
–Time
–Angle
– Torque
–Time
As of IPM version 6, different
graph data can be selected for
the AFO default values to be
able to reduce the amount of
data in the transfer of a data set.
OK graph List (expandable) – Last step
–All steps
– Docu steps +
result step
Last step Determination how the graph is
to be transmitted to the IPM
system in case of OK
–Last step
Graph range of the last
tightening step
– All steps
Entire tightening graph
– Docu steps
The corresponding graph
area will be assigned and
transferred for each
completed docu step. Each
step that is transferred to
the IPM system contains the
related graph area.
NOK graph List (expandable) – Last step
–All steps
– Docu steps +
result step
All steps Determination how the graph is
to be transmitted to the IPM
system in case of NOK
–Last step
Graph range of the last
tightening step
– All steps
Entire tightening graph
– Docu steps
The corresponding graph
area will be assigned and
transferred for each
completed docu step. Each
step that is transferred to
the IPM system contains the
related graph area.
Tension relief Option – checked
– not checked
checked – checked
Tension relief range is not
cut off
–Not ticked
Tension relief range is cut
off