Table 6–192: Settings in the BS350 for PFCS 2-Port
Element Description
interface Display of the Ethernet interface: eth
max-record-len Maximum length of the results data set.
Default setting: 1024
supported-modes Select the mode:
– PFCS server mode
Controller (CS, KE) in job mode:
– For data output in field result-modality, one of the job output modes (Job
ER: xxxx) has to be selected.
– Each job step refers to one screw, i.e. the OK count must always be 1, NOK
counts may be higher. This particularly applies for KE jobs!
– KE job: For a connection (client), precisely the application blocks that are
also used in the job have to be defined. The respective number of list
elements has to be added. This way, the PFCS driver is notified on which
application blocks and applications belong together as these tightening
results need to be transmitted in the same data set (depending on the set
mode).
– Field bus mode
– The controller must not be operated in job mode. Control of programs or
applications via I/O interface, e.g. field bus.
– TE / TD (ToolEnable / ToolDisable) Messages are always confirmed and
acknowledged with the character defined in field manual-only-ack-code.
– Special KE application range: For results output, two output methods can be
defined:
- An application result with all involved channels in one data set,
client[x] - setting: "fastening: FO" + "number: 1 - 8"
- All channels transmit their results via a dedicated connection with separate
port number,
client[x] - setting: "fastening: ApplChan" + "number: 0.1 - 15.6".
The FO block in which the application was running does not play any role.
Mixed operation of "result-modality" is not admissible. This means, the "result-
modality" setting must be identical for all connections.
Mixed operation of "fastening" is not admissible. This means, the "fastening" setting
must be identical for all connections.
Plausibility checks are currently not realized for the cases described above.
Default setting: PFCS server mode
manual-only-ack-code Selection of the character, TE / TD (ToolEnable / ToolDisable) messages are
confirmed with.
keep-alive-in-sec Waiting time in seconds for KeepAlive messages if no transmission is running.
Default setting: 120
reconnect-in-sec Waiting time in seconds for connection attempts.
Default setting: 12
connect-timeout-in-sec Waiting time in seconds for response of a connect request.
Default setting: 10
interval-stored-results-in-ms Pause in milliseconds between the transmission of saved results.
Default setting: 1000
label-type This character is filled into the Label Type field in the results string.
Default setting: CS
idcode-field Definition of the fields of the TE message to be used for the ID code if the PFCS2P
driver is selected under the ID code source:
CIS, VIN, VIN + CIS
Default setting: CIS