596/641 Bosch Rexroth AG | Tightening Technology 3 608 878 300
System 350 | 3 608 878 300/2019-03
ProfiNet master settings
Click Accept to transfer the data to the configuration for the tightening channel in the BS350.
As of version V2.500 of the Rexroth Tightening System 350, the GSDML file version "GSDML-V2.32-
Bosch_Rexroth_AG-Schraubsystem_350_IMpnio2-20161221.xml" is generated. In the configuration
tool of the communication partner, the access point (DAP; Device Access Point) corresponding to the
access point of the firmware version of the applied IMpnio2 interface module has to be selected.
To ensure communication of the Rexroth Tightening System 350 with the communication partner via the
IMpnio2 interface module without errors, observe the following information:
1. To read the firmware version of the applied IMpnio2 interface module in BS350, click in the BS350
menu bar on System test and then on Field bus... status.
2. In the configuration tool of the communication partner, select the access point (DAP; Device Access
Point) corresponding to the firmware version of the applied IMpnio2 interface module.
3. Configure the communication partner. Please proceed in the following order:
a. Configure the outputs first.
b. Then configure the inputs.
The ProfiNet cycle time during communication with the tightening system must not fall below 4ms.