3 608 878 300 Tightening Technology | Bosch Rexroth AG 597/641
System 350 | 3 608 878 300/2019-03
IMenip This parameter dialog consists of two index cards that can be selected in the Setup EtherNet/IP
interface group:
• I/O and data
• Configuration
Index card: I/O and data
No settings can be made in the Configured ranges field: The grayed out fields cannot be edited. The
parameters displayed in this field depend on the selected number of I/O points.
Index card: Configuration
The following settings can be made in this window:
• Get configuration via DHCP
or
• Use the following configuration: If you select this item, you can enter the following parameters:
– IP address: Assigned by the network administrator; identifies the participant in the data exchange
– Subnet mask: Assigned by the network administrator; contains information on the network
configuration (address range)
– Gateway: Establishes the external connection
• Host name: Name by which the Ethernet participant (here the KE of the tightening system) can be
addressed.
Create ESD file button
A participant profile in form of an EDS (electronic data sheet) file is required to commission the IMenip
interface module. The EDS file (*.eds) enables recognition of variable parameters and their value ranges
in the software.
After setting all parameters, create the EDS file by clicking Create EDS file.
Click Accept to transfer the data to the configuration for the tightening channel in the BS350.
Table 7–30: Settings in BS350 for IMenip - I/O and data
Element Description
Number of I points Number of control signals to be processed via the EtherNet/IP interface. Value
range 16 to 512 input signals (2 to 64 bytes)
Number of O points Number of control signals to be processed via the EtherNet/IP interface. Value
range 16 to 512 output signals (2 to 64 bytes)
Receive data Memory location for receiving the ID code, max. 254 bytes at 2 bytes for I points
Send data Memory location for sending results, max. 254 bytes at 2 bytes for
O points
Receive IL data Memory location for receiving IL data, max. 256 bytes at 0 bytes for I points
These data are processed using the IL function block ControlFieldbus.
Send IL data Memory location for sending of IL data, max. 254 bytes at 2 bytes for O points
These data are processed using the IL function block ControlFieldbus.
Example If 16I was selected as the number of I points and 32O as the number of O points, 16 inputs (= 2 bytes)
and 32 outputs (= 4 bytes) will also be available in the field bus configurator.