3 608 878 300 Tightening Technology | Bosch Rexroth AG 599/641
System 350 | 3 608 878 300/2019-03
IMenip2 IMenip2 is supported as of version V2.600 of the Rexroth Tightening System 350.
This parameter dialog consists of two index cards that can be selected in the Setup EtherNet/IP
interface group:
I/O and data
Configuration
Index card: I/O and data
No settings can be made in the Configured ranges field: The grayed out fields cannot be edited. The
parameters displayed in this field depend on the selected number of I/O points.
Index card: Configuration
You can select configuration either via DHCP = Dynamic Host Configuration Protocol or via specification
of the IP address with subnet mask and gateway.
Create ESD file button
A participant profile in form of an EDS (electronic data sheet) file is required to commission the IMenip2
interface module. The EDS file (*.eds) enables recognition of variable parameters and their value ranges
in the project planning software.
After setting all parameters, create the EDS file by clicking Create EDS file.
Click Accept to transfer the data to the configuration for the tightening channel in the BS350.
Table 7–31: Settings in BS350 for IMenip2 - I/O and data
Element Description
Number of I points Number of control signals to be processed via the EtherNet/IP interface. Value
range 16 to 512 input signals (2 to 64 bytes)
Number of O points Number of control signals to be processed via the EtherNet/IP interface. Value
range 16 to 512 output signals (2 to 64 bytes)
Receive data Memory location for receiving the ID code, max. 254 bytes at 2 bytes for I points
Send data Memory location for sending results, max. 254 bytes at 2 bytes for O points
Receive IL data Memory location for receiving IL data, max. 254 bytes at 2 bytes for I points
These data are processed using the IL function block ControlFieldbus.
Send IL data Memory location for sending of IL data, max. 254 bytes at 2 bytes for O points
These data are processed using the IL function block ControlFieldbus.
The IP parameters (IP address, Subnet mask and Gateway) under System test Field bus status
and in the channel or KE configuration at IMenip2 always correspond to the currently applied value. If the
network connection is lost, e.g. if the Ethernet line is disconnected at the interface module, these values
are invalid or 0.0.0.0.
Example If 16I was selected as the number of I points and 32O as the number of O points, 16 inputs (= 2 bytes)
and 32 outputs (= 4 bytes) will also be available in the field bus configurator.