FI002K0018v1100UK – THS/21 Instruction manual for installation, use and maintenance
INSTALLATION
102 ORIGINAL INSTRUCTIONS
3.8.5 Transit speed
By modifying the value of KT, the parameters BL and BM are automatically set to nominal values, respectively 30 x KT
and 60 x KT. BL and BM can also be modified manually.
The individual BS for each type of product is stored to memory.
3.8.5.1 Application with Control Power Box
These transit speed parameters set the speed of the product as it passes through the antenna.
These values are used to define the ejection cycle.
Programming menu
Remote
parameter
Description Allowed values
Configuration(adv) > K transmiss
KT
Gear motor transmission
constant
0
Configuration(adv) > Min speed
BL
Minimum transit speed
2 - BM m/min
Configuration(adv) > Speed
BS
*
Nominal transit speed
BL - BM m/min
Configuration(adv) > Max. speed
BM
Maximum transit speed
BL - 250 m/min
* Where an encoder is present (KE>0) this parameter is not available.
Set BL and BM values as close as possible to BS, according to the specified settings, as this can increase the Metal
Detector immunity to interference.
3.8.5.2 Application with Conveyor Control System
These transit speed parameters set the speed of the conveyor belt. These values are used to
regulate conveyor movements and to define the ejection cycle.
Programming menu
Remote
parameter
Description Allowed values
Configuration(adv) > K transmiss
KT
Gear motor transmission
constant
See procedure for the
motor connection
Configuration(adv) > Min speed
BL
Minimum transport speed
10 x KT - BM m/min
Configuration(adv) > Speed
BS
*
Transport speed
BL - BM m/min
Configuration(adv) > Max. speed
BM
Maximum transport speed
BL - MI x KT m/min
Configuration(adv) > Max inv.freq.
MI
Maximum inverter frequency
60 - 100 Hz
* Where an encoder is present (KE>0) this parameter is not available.
Set BL and BM values as close as possible to BS, according to the specified settings, as this can increase the Metal
Detector immunity to interference.