EasyManua.ls Logo

Ceia THS/MS21 - Test Procedure

Ceia THS/MS21
162 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FI002K0018v1100UK – THS/21 Instruction manual for installation, use and maintenance
4
USE OF THE DEVICE
ORIGINAL INSTRUCTIONS 135
4.8.2.1 Test procedure
The procedure below describes a test with a ferrous sample; the other two samples, made from
non-ferrous metal and in stainless steel, follow the same procedure.
For the double and the triple test (see TMD on Programming Manual), the tests will be requested
one after the other.
The execution of the tests and the final response will be recorded in the event log.
THS/21E THS/21
To perform the Metal Detector test
(independently or in response to the
automatic request), select MD Test >
FE test and press E key.
FE test -0.80 @
NFE test-1.00
SS test -1.20
FE
~
t
es
t
~-
0
.
80
~~~~~~~@
NFE test-1.00
SS test -1.20
Wait a few seconds, before
performing the sample transit.
=====================
WAIT
---------------------
[
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
]
WAIT
{|||||||||||||||||||}
Pass the requested sample, together
with the pure product, through the
probe within 1 minute
.
=====================
PASSE FE SAMPLE
---------------------
[
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
]
PASS FE SAMPLE
{|||||||||||||||||||}
If the sample is correctly detected and
ejected (through the Ejection
Confirmation check), the test is
successful.
=====================
TEST PASSED
---------------------
[
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
]
TEST PASSED
{|||||||||||||||||||}
Pressing any key, the display returns
to the MD test menu, where the
positive outcome is also shown.
FE test -0.80 OK
NFE test-1.00
SS test -1.20
FE
~
t
es
t
~-
0
.
80
~~~~~
OK
NFE test-1.00
SS test -1.20
Repeat the test with the non-ferrous and stainless steel samples.
If the test is unsuccessful, one of the following messages will be seen:
TEST FAILED for Sample not detected
THS/21E THS/21
If the sample is not detected it could
be that the transit was performed in
the 20 seconds immediately after the
request, or the sample signal is lower
than the alarm threshold.
=====================
TEST FE FAILED
NO SAMPLE DETECTED
---------------------
[
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
\
]
TEST FE FAILED
NO SAMPLE DETECTED
{|||||||||||||||||||}
Pressing any key, the display returns
to the MD test menu, where the
negative outcome is also shown.
FE test -0.80 NO(1)@
NFE test-1.00
SS test -1.20
1- NO SAMPLE DETECTED
FE
~
T
es
t
~-
0
.
80
~~
NO(1)
@
NFE Test-1.00
SS test -1.20
1- NO SAMPLE DETECTED