FI002K0018v1100UK – THS/21 Instruction manual for installation, use and maintenance
5
MAINTENANCE
ORIGINAL INSTRUCTIONS 139
5 MAINTENANCE
Before starting any installation operation, carefully read the Safety instructions – Warnings section of this manual.
Any maintenance or repair of the device while open and powered up should be avoided and in any case should only be
carried out by trained personnel who are fully aware of the risks which the operation entails, following the instructions
given in the Maintenance section.
When the mains is disconnected using the main switch of the Conveyor Control System, the power supply section is
deactivated, but any contacts which can be connected to the mains, e.g. the relay outputs, remain energized.
5.1 Periodic Maintenance
The following is a list of maintenance operations and their suggested frequency.
Operation Frequency Operator Procedure
Preventive maintenance
At the beginning of each shift
Operator
Visual check of the integrity of
the components and check of
safety components – Par.4.4.1
On changing product type
Periodically
Emptying the reject bin Periodically Operator Par. 4.5.6
Detection check
At the beginning of each shift
Quality control
operator;
Head of quality control
Section 4.8.2
On changing product type
Periodically
Checking the bearings
Periodically Operator
Visual check of bearing
efficiency and lack of lubricant
leaks.
Monthly (wet environments
subject to frequent washing)
Maintenance personnel Grease where specified
6 months (dry environments)
Cleaning
At the beginning of each shift Operator
Section 5.2.1 On changing product type
Operator
Periodically
Cleaning the conveyor belt When needed Operator Section 5.2.2
Emptying the compressed air filter
container
When needed Operator
Conveyor belt tension adjustment
(THS/FBB and THS/FB)
6 months or when needed Maintenance personnel Section 5.2.3
Locking terminals used to connect
control panels
6 months Maintenance personnel
Tightening the screws 6 months Maintenance personnel
The operator must monitor the condition of the system and its suitability for use and consult the maintenance personnel if
necessary.
5.2 Periodic Maintenance procedures
5.2.1 External cleaning instructions
Only use products compatible with stainless steel (AISI
316), PETG and silicon.
Use a slightly damp, non-abrasive cloth
Do NOT use HYDROCHLORIC
ACID or its solutions.
Do NOT use any other cleaning
procedure.
.