6.2.17 GETINPUTSTATUS
Summary: This command is used to get the current status of the selected Input
IO.
G E T I N P U T S T A T U S
Space
InputChannel
EOM
Input Operand: InputChannel - There are 2 input digital IO channels in the
system. Valid values are either 1 or 2.
If no InputChannel number is provided then the command will default to
InputChannel 1.
Return Values:
0 = Low
1 = High
6.2.18 OUTPUTENABLE
Summary: This command is used to enable the IO Output Driver circuitry. This
command must precede any activity that uses the IO Output Port. See the related
SETOUTPUT t command hat is used to control the state of the output.
Reference Command: SETOUTPUT
O U T P U T E N A B L E
Space
State
EOM
Input Operand: State - State can be either 0 for OFF (Disabled) or 1 for ON
(Enabled)
Return Values: None
605-7040 Operation Manual