2.4.2 Cables
Table 2-2 lists the SR-800R cabling.
Table 2-2: Cables
Length (meters)
# Name
Standard Max
From To Function
1. 110/230V ---
2.5m
16AWG
Mains SR-800R
SR-800R operation power.
CAUTION
Always disconnect the power cable
from Mains before replacing the
fuse or performing any
maintenance activities on the SR-
800R.
2. F12.5A --- --- ----------------
The SR-800R fuse is used to
protect the SR-800R components
from over-current. The fuse is
powered even when the SR-800R
is OFF.
CAUTION
Always disconnect the power cable
from Mains before replacing the
fuse or performing any
maintenance activities on the SR-
800R.
3. I/O --- 20m SR-800R I/O devices
A D-type 9-pin female connector -
contains five general-purpose
output channels, and two general-
purpose inputs, used to drive or
sense devices that may be
connected to these channels.
4. RS232 4m 15m SR-800R
Host
Computer
Standard RS232 communication
port (D-type 9-pin male connector)
used when the SR-800R Controller
operates under the control of a host
computer, or connected to the
system computer.
605-7040 Operation Manual
Rev D 2-7
June 2013