6.2.36 GETTEMPERATURERANGE
Summary: Use this command to return the absolute and differential temperature
ranges of the controller. Return 4 values delimited by commas.
Notes:
• For an Absolute Head Model only
, the values returned for the
minimum/maximum differential temperatures will be 0 (see Return3 and
Return4).
• This command replaces the RG command for new applications.
G E T T E M P E R A T U R E R A N G E
EOM
Input Operand: None.
Return Values:
• Return1 - double - Minimum Absolute Temperature.
• Return2 - double - Maximum Absolute Temperature.
• Return3 - double - Minimum Differential Temperature.
• Return4 - double – Maximum Differential Temperature.
605-7040 Operation Manual