65-9
Software Configuration Guide—Release IOS XE 3.6.0E and IOS 15.2(2)E
OL_28731-01
Chapter 65 Configuring Flexible NetFlow
Non-VSS Environment
!
flow monitor m1
! monitor refers record configuration and optionally exporter
! configuration. It specifies the cache size i.e. how many unique flow
! records to collect
record r1
exporter e1
cache timeout active 60
cache timeout inactive 30
cache entries 1000
!interface GigabitEthernet 3/1
! layer2-switched allows collection of flow records even when the packet is
! bridged
ip flow monitor m1 layer2-switched input
!
interface GigabitEthernet 3/2
ip flow monitor m1 input
!
2. Flow collection is supported on multiple targets (Port, VLAN, per-port per-VLAN (FNF can be
enabled on a specific VLAN on a given port)) and on a port-channel (FNF is configured on the
port-channel interface, rather than individual member ports).
3. 64 unique flow record configurations are supported.
4. Flow QoS/UBRL and FNF cannot be configured on the same target. (For information on Flow-based
QoS, see the section Flow-based QoS, page 42-10.)
5. 14,000 unique IPv6 addresses can be monitored.
6. On a given target, one monitor per traffic type is allowed. However, you can configure multiple
monitors on the same target for different traffic types.
For example, the following configuration is allowed:
! vlan config 10
ip flow monitor <name> input
ipv6 flow monitor <name> input
!
The following configuration is not allowed:
!
interface GigabitEthernet 3/1
ip flow monitor m1 input
ip flow monitor m2 input
7. On a given target monitoring Layer 2 and Layer 3, simultaneous traffic is not supported:
interface channel-group 1
datalink flow monitor m1 input
ip flow monitor m2 input
!
8. Selection of Layer 2 and Layer 3 packet fields in a single flow record definition is disallowed.
However, ingress 802.1Q VLAN Id of packet and Layer 3 packet field selection is allowed.
9. To attach a monitor to port or port-vlan targets, a flow record matching on ingress 802.1Q VLAN Id
as the key field, must also match on the input interface as the key field.
Note Flow monitor matching on ingress 802.1Q VLAN Id as the key field cannot be attached on a
VNET trunk port target.
10. Only permanent and normal flow cache types are supported.