seeprom: Pass
Traffic: L3 Looopback ...
Test Results: Pass
Traffic: L2 Loopback ...
Test Results: Pass
post done
Exiting to ios...
The following example shows the output from the show diagnositic result command for Supervisor
Engine 6-E and Supervisor Engine 6L-E:
Switch# show diagnostic result module 3 detail
module 3: SerialNo : XXXXXXXXXXX
Overall diagnostic result: PASS
Test results: (. = Pass, F = Fail, U = Untested)
___________________________________________________________________________
1) supervisor-bootup --------------->
Error code ------------------> 0 (DIAG_SUCCESS)
Total run count -------------> 1
Last test execution time ----> Oct 01 2007 17:37:04
First test failure time -----> n/a
Last test failure time ------> n/a
Last test pass time ---------> Oct 01 2007 17:37:04
Total failure count ---------> 0
Consecutive failure count ---> 0
Power-On-Self-Test Results for ACTIVE Supervisor
prod: WS-X45-SUP6-E part: XXXXXXXXX serial: XXXXXXXXXX
Power-on-self-test for Module 3: WS-X45-SUP6-E
Test Status: (. = Pass, F = Fail, U = Untested)
CPU Subsystem Tests ...
seeprom: Pass
Traffic: L3 Loopback ...
Test Results: Pass
Traffic: L2 Loopback ...
Test Results: Pass
Switching Subsystem Memory ...
Packet Memory Test Results: Pass
Module 3 Passed
___________________________________________________________________________
2) linecard-online-diag ------------>
Error code ------------------> 0 (DIAG_SUCCESS)
Total run count -------------> 1
Last test execution time ----> Oct 01 2007 17:37:04
First test failure time -----> n/a
Last test failure time ------> n/a
Last test pass time ---------> Oct 01 2007 17:37:04
Total failure count ---------> 0
Consecutive failure count ---> 0
Slot Ports Card Type Diag Status Diag Details
---- ----- -------------------------------------- ---------------- ------------
3 6 Sup 6-E 10GE (X2), 1000BaseX (SFP) Skipped Packet memory