EasyManua.ls Logo

Comtech EF Data CDM-570AL - Page 168

Default Icon
682 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CDM-570A/570AL Satellite Modem with Optional Packet Processor
Revision 5
Front Panel Operation 6–52 MN-CDM570A
When you do not enable AUPC, both maximum and average TPLI shows 0.0'.
Examples: 08.0,13.5,2.5,1.8 means:
Minimum E
b
/N
0
observed in the measurement interval = 8.0 dB
Average E
b
/N
0
observed in the measurement interval = 13.5 dB
Maximum TPLI observed in the measurement interval = 2.5 dB
Average TPLI observed in the measurement interval = 1.8 dB
Loss,04.5,0.0,0.0 means:
There was a loss of demod lock during the measurement interval
Average E
b
/N
0
observed in the measurement interval = 4.5 dB
Maximum TPLI observed in the measurement interval = AUPC disabled
Average TPLI observed in the measurement interval = AUPC disabled
The presentation of statistics information varies slightly when in VersaFEC ACM (IP-ACM) or
VersaFEC-2 ACM (V2-ACM) mode.
In VersaFEC ACM (IP-ACM) mode:
Sta198:02/11/13 10:37:32
16.0,16.0,2,4,0,0 (▲ ▼)
The bottom line calculates and then displays statistics data as follows:
Example: 16.0,16.0,2,4,0,0 means:
Minimum E
b
/N
0
observed in the measurement interval = 16.0 dB
Average Eb/N0 observed in the measurement interval = 16.0 dB
The Rx ModCod, in hex format, that was current when the entry was logged = 2
Maximum Rx ModCod, in hex format, during the measurement interval = 4
Minimum Rx ModCod, in hex format, during the measurement interval = 0
Number of Rx ModCod changes, in hex format, during the measurement interval = 0

Table of Contents