CDM-570A/570AL Satellite Modem with Optional Packet Processor
Revision 5
Serial-based Remote Product Management 8–24 MN-CDM570A
8.5.4 Unit Parameter Commands and Queries
Parameter
Type
(Instruction
Code and
Qualifier)
Command or
Response to
Query
Description of Arguments
Response to
Command
Query
(Instruction Code
and Qualifier)
Response to
Query
value of 0 or 1
Sets or returns the CDM-570/CDM-570A compatible status in the form x, where:
0 = CDM-570 Compatible Mode
1 = CDM-570A Compatible Mode
Example: <0/CMO=1 (CDM-570A Compatible Mode)
CMO?
CMO*
CMO#
(see Description of
Arguments)
Status
value of 0, 1 or 3
Sets or returns Local/Remote status in the form x, where:
0 = Local
1 = Serial Remote
3 = Ethernet Remote
Example: <0/LRS=1 (Serial Remote)
LRS?
LRS*
LRS#
LRS+
(see Description of
Arguments)
Lockout
value of 0 or 1
Sets or returns the front panel lockout state in the form x, where:
0 = no lockout
1 = front panel lockout active
Disable the lockout by either FPL=0, or by setting into local mode using LRS=0
(response is LRS+ meaning FPL is disabled at the same time)
Note: When using the Optional Packet Processor Command Line Interface (CLI),
to verify CLI lockout:
<0/FPL?
>0/FPL=0 (Lockout disabled) or
>0/FPL=1 (Lockout enabled)
FPL?
FPL*
FPL#
(see Description of
Arguments)
value of 1 or 2
Sets or returns Current Active software image in the form x, where:
1 = Bulk Image # 1 currently active
2 = Bulk Image # 2 currently active
Example: <0/IMG=1 (Image #1 active)
IMG?
IMG*
IMG#
(see Description of
Arguments)
Sets or returns the user-defined Circuit ID string.
Note: Circuit ID string is a fixed length of up to 24 characters. Valid characters
include: [Space] ( ) * + – , . / 0 thru 9 and A thru Z
CID?
CID*
xxxxxxxxxxx
(see Description of