CDM-570A/570AL Satellite Modem with Optional Packet Processor
Revision 5
Serial-based Remote Product Management 8–16 MN-CDM570A
Parameter
Type
(Instruction
Code and
Command or
Response to
Description of Arguments
Response to
Command
Query
(Instruction Code
and Qualifier)
Response to
Query
Mode
value of 0, 1, 2
Sets or returns Power level mode in the form x, where:
0 = MANUAL mode (Normal power mode)
1 = AUPC enabled.
2 = CnC APC enabled
Notes:
1. EDMAC framing and/or IP-ACM must be selected for the AUPC feature to work.
2. CnC APC will be forced to enable when CnC is in APC mode (CNM=2 ..9)
AUP?
AUP*
AUP#
(see Description of
Arguments)
Not valid in Manual mode.
Sets or returns AUPC operating parameters, in the form abc.cd, where:
a = Defines action on max. power condition.
0 = do nothing
1 = generate Tx alarm
b = Defines action on remote demod unlock.
0 = go to nominal power
1 = go to max power
c = Target E
b
/N
0
value, for remote demod, from 0.0 to 14.9 dB, where numbers >9.9
use hex representation for the 1 st character, i.e., 14.9 is coded as E.9.
d = Max increase in Tx Power permitted, from 0 to 9 dB
Example: <0/APP=015.67 (Sets no alarm, max power, 5.6 dB Target and 7 dB power
increase.)
In IP-ACM mode:
a=Defines action on max. power condition.
0 = do nothing
1 = generate Tx alarm
2=generate Tx alarm when mimimum ModCod is reached
b=Defines action on remote demod unlock.
0 = go to nominal power
1 = go to max power
2=hold
c = Max increase in Tx Power permitted, from 0.0 to 9.9 dB OR when CnC mode is
on, from 0.0 to 3.0 dB
APP?
APP*
APP#
(see Description of
Arguments)