CDM-570A/570AL Satellite Modem with Optional Packet Processor
Revision 5
Serial-based Remote Product Management 8–57 MN-CDM570A
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
Response to
Command
Query
(Instruction Code
and Qualifier)
Response to
Query
CnC-APC Max
Power Level
Increase
APL=
3 bytes
Command or Query.
Valid only in CDM-570A Compatible Mode (CMO=1).
Sets or returns CnC-APC maximum power level increase, limited by Tx power
level, in the form xx.x, where:
xx.x = value from 0.0 to 9.9 dB,.
Example: <0/APL=3.9 (APC max power level increase is 3.9 dB.)).
APL=
APL?
APL*
APL#
APL?
APL=xx.x
(see Description of
Arguments)
CnC-APC
Home State
AHS=
12 bytes
Command or Query.
Valid only in CDM-570A Compatible Mode (CMO=1).
Note: Command is only for Offline unit, sent by switch in a 1:N Redundancy
system, or Online unit in a 1:1 Redundancy system.
Returns CnC-APC home state parameters in the form a,bbb,cc,ddd, where:
a = APC state. (1 = APC is active, 0 = APC is not active)
bbb = APC home state Tx power, in 0.1dB. (minus sign assumed)
cc = APC home state max power level increase, in 0.1 dB.
ddd = APC Tx power threshold, in 0.1 dB. (minus sign assumed)
Example: <0/AHS=1,100,60,085 (APC is active, home state power is -10.0 dB,
home state max power level increase is 6.0 dB, power threshold is -8.5 dB)
AHS=
AHS?
AHS*
AHS#
AHS?
AHS=a,bbb,cc,ddd
(see Description of
Arguments)

Table of Contents