11. Tech. Rep. Mode Field Service Ver. 1.0 Aug. 2005
192
bizhub 200/250/350
Adjustment / Setting
0010 RX FIF0 ERROR
(when Read / Write error occurs at RX FIF0)
• Contact responsible person of
KONICA MINOLTA.
0011 Baud Rate ERROR
(When selected Baud Rate is out of the specifica-
tion (9600 bps to 38400 bps).)
• Check the Baud rate of the
software DipSW.
0012 TX FIF0 Level Error
(When the threshold of the selected TX FIF0 is
not error value (1, 3, 9, 13).)
• Contact responsible person of
KONICA MINOLTA.
0013 RX FIF0 Level Error
(When the threshold of the selected RX FIF0 is
not error value (0, 4, 8, 14).)
• Contact responsible person of
KONICA MINOLTA.
0014 Receiving Data Over Error
(When the data whose size exceeds the transmit-
ting RING buffer is requested.)
• Contact responsible person of
KONICA MINOLTA.
0015 Status Error
(During modem operation is being confirmed)
• Contact responsible person of
KONICA MINOLTA.
0016 Status Error (During receiving) • Contact responsible person of
KONICA MINOLTA.
0017 Status Error
(During line is being shut down)
• Contact responsible person of
KONICA MINOLTA.
0018 Machine ID has already been registered
(Request telegram 2 (SET-UP) comes from the
main unit that has already registered Machine
ID.)
• Set the initial registrations
again for all including the host
side.
0019 Center ID Error
(Center ID of the host is not identical with the one
of start request telegram.)
• Check Center ID setting of the
main unit side.
• Check Center ID setting of the
main unit side.
001A Device ID inconsistency
(Device ID of the host is not identical with the one
of start request telegram.)
• Check Device ID setting of the
main unit side.
• Check the setting of the host
side.
001B Device ID Unregistered
(Request telegram 2 (Constant data transmitting,
Emergency call) comes from the main unit that
has not registered Machine ID yet.)
• Check Device ID setting of the
main unit side.
• Check the setting of the host
side.
001C Grammar Error
(Received response telegram is unregulated for-
mat.)
• Contact responsible person of
KONICA MINOLTA.
001D Impossible to change (Unchangeable items)
(Host requests to change the setting of items
which are not allowed to change.)
• Contact responsible person of
KONICA MINOLTA.
001E Impossible to change (During printing)
(Setting cannot be changed because the setting
change is made during the machine is printing or
starts printing.)
• Try again when the machine is
not printing.
001F Impossible to change (Unread items)
(The host tries to make writing on the items the
current value has not been read.)
• Contact responsible person of
KONICA MINOLTA.
Error code Error Solution