11. Soft Switch List Field Service Ver. 1.0 Aug. 2005
124
FK-503
Adjustment / Setting
NOTE
The features with (*) are settable by users. *: Screen setting
NOTE
The features with (*) are settable by users. *: Screen setting <*>: Soft switch setting
MODE Factory setting bit
405
Bit: 7654 3210
0000 1111
HEX:0F
Bit Feature
Logic
Description
01
7 Select pre-heating time. * Bit 7-0: 00000001 1 min For every 1 min
Select whether to carry
out auto-clear if there is
no operation for certain
time, after copy or oper-
ation.
6|
5 00000101 5 min
|
4
00001111 15 min
|
3 11110000 240 min
2 Others Not available
1
0
MODE Factory setting bit
406
Bit: 7654 3210
0000 0001
HEX:0F
Bit Feature
Logic
Description
01
7 Select sleep off time. * Bit 7-0: 00000000 OFF For every 1 min
Select whether to carry
out “auto power-source
off” if there is no opera-
tion for certain time, after
copy or operation. Also,
select its time.
“Auto Power source off
is not carried out if
“Select auto Power
source off (MODE 416
Bit 0)” is set to “No.
6 00000001 1 min
00001111 15 min
5|
4 00011110 30 min
3|
2 00111100 60 min
1|
0 11110000 240 min
Others Not available