460 Service Instructions 755 A/756 A - 00.0 - 02/2019
4683 No valid sequence number Check communication
Change sequence
Compare software version of DAC
and OP7000
Error code 5000-5999: Error messages machine configuration
5108 - Use USB file from this machine.
5201 Error step motor corner knife,
slanted seam end
Check cable to reference switch
Check reference switch
Check motor for stiff movement
5202 Error step motor corner knife,
slanted seam beginning
Check cable to reference switch
Check reference switch
Check motor for stiff movement
5203 Error step motor corner knife,
angle seam begin right
Check cable to reference switch
Check reference switch
Check motor for stiff movement
5204 Error step motor corner knife,
angle seam begin left
Check cable to reference switch
Check reference switch
Check motor for stiff movement
5205 Error step motor corner knife,
angle seam end right
Check cable to reference switch
Check reference switch
Check motor for stiff movement
5206 Error step motor corner knife,
angle seam end left
Check cable to reference switch
Check reference switch
Check motor for stiff movement
5209 Error horizontal step motor mark-
ing lamp
Check cable to reference switch
Check reference switch
Check motor for stiff movement
5210 Error vertical step motor marking
lamp
Check cable to reference switch
Check reference switch
Check motor for stiff movement
Error code Symbol Meaning Remedial action