Error code 6000-6999: Error messages control
6000 Internal error Switch off and on the machine
again
Perform software update
p. 431
Inform Dürkopp Adler Customer
Service
6301 Data loaded from the machine ID Check machine configuration
6351 Control defective (I2C) Replace control
6353 Internal EEprom communication
error
Switch off the control, wait until the
LED has gone out, and then switch
on the machine again
6354 Machine ID communication error Switch off the control, check the
connection to the machine ID
6360 Data of machine ID not valid for
this machine
Connect correct machine ID
6361 No machine ID connected Connect machine ID
6400 Internal error Switch off and on the machine
again
Perform software update
p. 431
Inform Dürkopp Adler Customer
Service
6401 Default data loaded Check machine configuration
6408 Use USB data from this machine
6551, 6552 Error in machine head position
AD converter
internal process error
Switch off and on the machine
again
Perform software update
p. 431
Inform Dürkopp Adler Customer
Service
6553, 6554 Error in machine head position
AD converter
internal process error
Switch off and on the machine
again
Perform software update
p. 431
Inform Dürkopp Adler Customer
Service
Error code Symbol Meaning Remedial action