Troubleshooting
208 Service Instructions M-TYPE DELTA - 00.0 - 12/2019
1007 Error Error in the reference run Replace encoder
Check for stiff movement
1008 Error Sewing motor encoder error Replace encoder
1010 Error External synchronizer plug
(Sub-D, 9-pin) not connected
Connect cable of external
synchronizer to control, make sure
that interface (Sync) is correct
Only recommended for machines
with transmission!
1011 Error Encoder Z pulse missing Switch off the control, use
handwheel to turn, and switch on
the control again
If error is not corrected, check
encoder
1012 Error Synchronizer fault Replace synchronizer
1054 Error Internal short circuit Replace control
1055 Error Sewing motor overload Check for stiff movement
Replace encoder
Replace sewing motor
1060 Error Sewing motor overload / overvoltage /
overcurrent
Check selection of class
Replace control
Replace motor
Replace encoder
1061 Error Sewing motor overload / overvoltage /
overcurrent
Check selection of class
Replace control
Replace motor
Replace encoder
1120 Error Sewing motor Init fault Perform a software update
Check selection of class
1121 Error Sewing motor watchdog Perform a software update
Check selection of class
1203 Error Position not reached (during thread
cutting, reversal, etc.)
Check the controller settings and
change them if necessary
(e.g. thread trimmer setting, belt
tension, etc.)
Check position thread lever at top
dead center
1302 Error Failure with sewing motor current Check Service Stop
Check for stiff movement
Replace encoder
Replace motor
1330 Error No response from sewing motor Perform a software update
Replace control
2101 Error Stepper motor X30 reference run
timeout
Check reference sensor
2105 Error Stepper motor card X30 blockage Check for stiff movement
2121 Error Stepper motor card X30 encoder plug
(Sub-D, 9-pin) not connected
Connect encoder cable to the
control, use the correct interface
2122 Error Stepper motor card X30 flywheel
position not found
Check stepper motor 1 for stiff
movement
Code Type Meaning Remedial action

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DURKOPP ADLER D867 M-Type Delta and is the answer not in the manual?

DURKOPP ADLER D867 M-Type Delta Specifications

General IconGeneral
BrandDURKOPP ADLER
ModelD867 M-Type Delta
CategorySewing Machine
LanguageEnglish

Related product manuals