1007 Error Error in the reference run • Replace encoder
• Check for stiff movement
1008 Error Sewing motor encoder error • Replace encoder
1010 Error External synchronizer plug
(Sub-D, 9-pin) not connected
• Connect cable of external
synchronizer to control, make sure
that interface (Sync) is correct
• Only recommended for machines
with transmission!
1011 Error Encoder Z pulse missing • Switch off the control, use
handwheel to turn, and switch on
the control again
• If error is not corrected, check
encoder
1012 Error Synchronizer fault • Replace synchronizer
1054 Error Internal short circuit • Replace control
1055 Error Sewing motor overload • Check for stiff movement
• Replace encoder
• Replace sewing motor
1060 Error Sewing motor overload / overvoltage /
overcurrent
• Check selection of class
• Replace control
• Replace motor
• Replace encoder
1061 Error Sewing motor overload / overvoltage /
overcurrent
• Check selection of class
• Replace control
• Replace motor
• Replace encoder
1120 Error Sewing motor Init fault • Perform a software update
• Check selection of class
1121 Error Sewing motor watchdog • Perform a software update
• Check selection of class
1203 Error Position not reached (during thread
cutting, reversal, etc.)
• Check the controller settings and
change them if necessary
(e.g. thread trimmer setting, belt
tension, etc.)
• Check position thread lever at top
dead center
1302 Error Failure with sewing motor current • Check Service Stop
• Check for stiff movement
• Replace encoder
• Replace motor
1330 Error No response from sewing motor • Perform a software update
• Replace control
2101 Error Stepper motor X30 reference run
timeout
• Check reference sensor
2105 Error Stepper motor card X30 blockage • Check for stiff movement
2121 Error Stepper motor card X30 encoder plug
(Sub-D, 9-pin) not connected
• Connect encoder cable to the
control, use the correct interface
2122 Error Stepper motor card X30 flywheel
position not found
• Check stepper motor 1 for stiff
movement
Code Type Meaning Remedial action