7.7.1 Installation drawing of the EMP III pump
Fig. 14: Installation drawing of the EMP III pump
Procedure:
1. Fix the pump bracket (no. 1) to the bracket (4x) using the screws and washers
supplied (no. 2).
2. Fix the EMP III pumps (no. 3) to the pump bracket using screws and washers (no. 4)
in the threaded insert bush.
3. Place hose nipple with union nut (no. 6) on the pump head.
4. Connect the EVA pipe to the suction and pressure sides.
5. Start the pumps and check all connections for leaks.
7.8 Upgrading the diaphragm valve manifold
7.8.1 Upgrade kits
Illustration Description Material Item No. EBS no.
Block extension, 2-way
Product side
PVDF 201714 10038289
Block expansion, 2-way
Machine side
PVDF 201715 10038287
Installation
60MAN046590 Rev. 6-03.2022