13.2.1.9.7 Pump capacity for type 01200 / 0.3 MPa (3 bar)
13.3 Metering pump TCD Turbo Pump
13.3.1 T
echnical Data
13.3.1.1 General data
Data Value Unit
Dosing back pressure
max. 2 (0,2) bar (MPa)
Suction height
1,5 m (Ws)
Environmental temperature (max. permissible)
10 - 40 °C
Connections
Ø 10 / 16 mm
Power supply
230 / 50 V / Hz
Current uptake
1 A
Type of protection
IP 42
Pump type 1070 / 107010:
Data Value Unit
Pump output
ca. 50 l/h
Rotational speed
125
min
-1
Duty cycle
25 % ED, (5) (max. duration
min)