3 INSTALLATION AND COMMISSIONING
2.3 Medium
Neutral liquids, in particular water and water containing additives, which do not
attack the housing and the sealing material.
Sealing material: NBR
Housing material: PA
Minimum pressure difference for complete opening of the valve: 1 bar
ATTENTION!
Continual pressure surges can shorten the service life of the
diaphragm!
3.1 Installation
Î Before installing the valve, clean the piping system!
Î Where necessary, fit a strainer upstream to protect against faults!
Î Observe the direction of flow!
Î Seal the thread using PTFE tape.
Î When installing the valve, ensure that the valve block is not distorted:
- provide adequate support for the piping system
- align the piping system
Maximum permissible torque M
t
:
for G 3/4" connections from plastic:
4 Nm
Maximum permissible bending moment M
B
:
for all connections:
6 Nm
ATTENTION!
Do not use the pilot valve as a lever when screwing in the
pipe connection!
Do not distort the valve housing during the installation!
Max. ambient temperature for continuous operation: +55 °C!