Maintenance 4. Cable
196 N6 Rev.2
6)
Disconnect the external short connector.
Disconnect the M/C cable.
For details, refer to Maintenance 4.6. M/C Cable.
Cut off the cable tie of the cables.
Be careful not to cut the cables.
Remove the user attachment of the Arm #4.
Hexagon socket head cap bolts: 2-M4×8
Cables are connected to the user attachment.
When you disconnect the cables, make sure
not to pull the user attachment forcibly.