Maintenance 6. Battery
N6 Rev.2 325
6.1 Replacing the Battery Unit (Lithium Metal Battery)
(1)
Turn OFF the controller.
(2)
Remove the Joint #2 outside cover.
N6-A1000**
N6-A850**R
Cross recessed binding head
machine screws: 3-M4×8
Cross recessed binding head
machine screws: 6-M4×8
(3)
Remove the old batteries from the battery box.
Do not disconnect the connectors.
If you remove all batteries before connecting
the new ones, the calibration data will
be deleted and you will need to perform calibration.
N6-A1000**
N6-A850**R
(4)
Connect the two new batteries to the connectors of
the battery board which is nothing
is
connected.
N6-A1000**
N6-A850**R
NOTE