EasyManuals Logo

Extron electronics DMP 128 FlexPlus User Manual

Extron electronics DMP 128 FlexPlus
190 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #145 background imageLoading...
Page #145 background image
DMP 128 FlexPlus • Remote Control and Configuration 136
Command ASCII command
(host to device)
Response
(device to host)
Additional description
Reboot Commands
Reboot system
E1BOOT} Boot1]
Reboot network
E2BOOT} Boot2]
Serial Host Control Port Mode
Standard host control
(SIS)
EX!*1HSTM} HstmX!*1]
Device control (no SIS)
EX!*2HSTM} HstmX!*2]
Disable port
EX!*0HSTM} HstmX!*0]
Query port mode
EX!HSTM} X8%]
Ping
Execute test
E{address/name}
PING}
{address}*{bytes}*
{ttl}*{time}]
Example:
E192.168.254.254
PING
}
192.168.254.254*64*
64*3.469
If ping fails to get reply
from address
{address}*0*0*0]
Timezone and Daylight Settings
Set time zone
E{zone name}*
TZON}
Tzon{zone name,
description}]
View current time zone
ETZON}
{zone name,
description}]
List all time zones
E*TZON}
{zone name,
description}]
...]
...]]
KEY:
X!
= Port Number 01 (always 01 for DMP 128 FlexPlus)
X8%
= Port Mode 0 = disabled, 1 = standard (default), 2 = device
PRELIMINARY
PRELIMINARY

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Extron electronics DMP 128 FlexPlus and is the answer not in the manual?

Extron electronics DMP 128 FlexPlus Specifications

General IconGeneral
BrandExtron electronics
ModelDMP 128 FlexPlus
CategoryComputer Hardware
LanguageEnglish

Related product manuals