Ranger HRC™ operator´s manual – Hardware installation
Publ. No. TM 614 006 699 Rev B – ENGLISH (EN) – Oct 30. 2008 121
9.3.4 Camera adjustments
9.3.4.1 Azimuth adjustment
Figure 9.13 Azimuth adjustment screws
Azimuth adjustment
Step Action
1 Loosen the four screws that are marked with rings in Figure 9.13 a bit.
2 Adjust the camera position with the azimuth adjustment screw, which is marked with
an arrow in Figure 9.13. Loosen the screw to turn the camera towards the center of the
system, and tighten the screw to turn the camera away from the center.
3 When the position of the camera is correct, cross-tighten the four screws that are marked
with rings in Figure 9.13. (Do not tighten the azimuth adjustment screw.)