Ranger HRC™ operator´s manual – Optimizing the IR Image
Publ. No. TM 614 006 699 Rev B – ENGLISH (EN) – Oct 30. 2008 157
justments have been made, the system may need to be set to the starting
point manually before the optimizing procedure starts.
12.1.1.1 Display indicators
The top line status indicators and the temperature range indicator for the
IR Camera provide a quick overview of the current settings. These indica-
tors are not displayed by default, but are made visible via the IR Camera
menu system.
Figure 12.1 IR Camera top line status indicator.
Figure 12.2 Temperature range indicator.
NOTE: When the IR Camera menu system is not opened, the temperature range indica-
tor is hidden behind the system information.
Displaying IR Camera indicators
Step Action
1 Press the ENTER button to enter MENU mode.
2 Select IR menu from the Setup menu and press the ENTER button. The menu system of
the IR Camera is opened.
3 Select Setup and press the ENTER button.
4 Select GUI… and press the ENTER button. The GUI Setup dialog box is displayed.
5 Select Upper status.
6 Use the LEFT/RIGHT navigation buttons to select On.
7 Select Temp range.
8 Use the LEFT/RIGHT navigation buttons to select On.
9 Press the ENTER button to conrm.
10 Press the CANCEL button to exit the IR Camera menu system.