Ranger HRC™ operator´s manual – System software
Publ. No. TM 614 006 699 Rev B – ENGLISH (EN) – Oct 30. 2008 53
7.4.1.3 Route sequence
The Route sequence dialog box is used to dene the sequence in which the
autoscan points in the currently loaded autoscan list shall be scanned.
The Route sequence dialog box is also used to inactivate autoscan points;
that is, to exclude the point from the currently loaded autoscan list. In-
activated autoscan points are still available and can be activated again at
any time.
Figure 7.10 Route sequence dialog box.
Route sequence dialog box
Feature Description
Active The Active item displays the current sequence of the autoscan points and is
used to manage the route sequence. The procedure for managing the route
sequence is described in section 11.4.2.6.
Inactive The Inactive item displays the inactive autoscan points and is used to
activate/deactivate autoscan points. The procedure for activating/deactivating
autoscan points is described in section 11.4.2.6.
7.4.1.4 Store/recall position list
The Store/recall position list dialog box is used to store, recall and delete
autoscan lists. It is possible to store up to four different lists (A, B, C and
D), with up to 32 autoscan points in each list.
The currently loaded and active autoscan list is possible to store. Pre-
viously stored autoscan lists are possible to recall and load as the active
autoscan list. It is also possible to delete previously stored autoscan lists.
NOTE: When an autoscan list is recalled, the currently active autoscan list is overwritten.
If the operator wants to store the currently active autoscan list, it must be done before
recalling another list.