Ranger HRC™ operator´s manual – Technical appendices
226 Publ. No. TM 614 006 699 Rev B – ENGLISH (EN) – Oct 30. 2008
The Ranger HRC MS systems are connected to a LAN switch via the JPC2
units. Each system is powered from its own Power Supply unit. The JCU
can be connected to the PC with an adapter cable, which also includes an
AC converter.
15.9.1 Equipment
The following equipment is needed for the IP network option:
One or several Ranger HRC MS systems, with JPC2 units congured
for the IP option.
One Power Supply unit per system.
One non-crossover FTP/STP cable per system for connection to the
LAN switch.
A crossover FTP/STP cable for connection of a standard PC directly
to the JPC2 units for change of network settings etc.
A COTS LAN switch 10/100 Mb or 10/100/1000 Mb).
A standard PC running a suitable security and surveillance applica-
tion, for example the FLIR Nexus application.
Optionally a Joystick Control Unit JCU).
Optionally an adapter cable for connection of the Joystick Control
Unit to the PC.