Ranger HRC™ operator´s manual – Optimizing the IR Image
174 Publ. No. TM 614 006 699 Rev B – ENGLISH (EN) – Oct 30. 2008
12.2.4.1 Internal NUC
Internal NUC
Step Action
1
Press button
NUC < 1 second to perform an Internal NUC.
NOTE: If the default setting for the NUC button has been changed (Setup-Image
dialog box, see section 7.6.1.1), the
NUC button shall be pressed > 1 second to
perform an Internal NUC.
As an alternative to using the JCU as described above, the IR Camera
menu system can be used:
Internal NUC
Step Action
1 Select Setup/IR menu to open the IR Camera menu system.
2 Select Setup/Image…/Shutter.
3 Use the LEFT/RIGHT navigation buttons to select Internal.
4 Press the ENTER button to conrm.
5 Press the ENTER button to re-open the IR Camera menu system.
6 Select Image…/NUC.
7 Press the LEFT or RIGHT navigation button or ENTER to perform a NUC.
8 Press the CANCEL button to exit the IR Camera menu system.
12.2.4.2 External NUC against lens cover
External NUC against lens cover
Step Action
1
Press buttons
FCN + NUC < 1 second to perform an External NUC against the lens
cover.
NOTE: If the default setting for the FCN + NUC button has been changed (Setup-
Image dialog box, see section 7.6.1.1), the FCN + NUC buttons shall be pressed
> 1 second to perform an External NUC.