Ranger HRC™ operator´s manual – System operation
Publ. No. TM 614 006 699 Rev B – ENGLISH (EN) – Oct 30. 2008 149
Managing the route sequence
Step Action
1 Ensure that IR is selected. If not, press the TV/IR button to select IR.
2 Press the ENTER button to enter MENU mode.
3 Select Route sequence… from the Pan/Tilt menu and press the ENTER button. The
Route sequence dialog box is displayed.
4 Use the LEFT/RIGHT and UP/DOWN navigation buttons to select the autoscan point to be
affected.
NOTE: The system will move to the position of the selected autoscan point.
5 Press the FCN button to allow changes of the selected autoscan point.
6 a Use the LEFT/RIGHT navigation buttons to move the point within the autoscan list.
6 b Use the UP/DOWN navigation buttons to move the point from active to inactive status, or
vice versa.
7 a Press the FCN button to accept the changes. A new autoscan point can now be selected.
Repeat from step 4.
7 b Press the ENTER button to accept the changes and to exit MENU mode.
11.4.2.7 Storing/recalling/deleting autoscan lists
This section describes how autoscan lists are stored, recalled and dele-
ted.
It is possible to store up to four different lists (A, B, C and D). It is also
possible to save the currently active autoscan list, see section 11.4.2.8.
NOTE: When an autoscan list is recalled, the currently active autoscan list is overwrit-
ten. If the operator wants to store the currently active autoscan list, it must be done
before recalling another list.