Ranger HRC™ operator´s manual – Technical appendices
Publ. No. TM 614 006 699 Rev B – ENGLISH (EN) – Oct 30. 2008 221
15.7 Diagnostic tools
The Ranger HRC MS system has an integrated series of diagnostic tests.
The Setup Diag tool dialog box is used to run the Focus, FOV, Pan/Tilt,
GPS, LRF and DMC diagnostic tests.
Figure 15.15 Setup – Diag tool dialog box.
Running diagnostic test
Step Action
1 Press the ENTER button to enter MENU mode.
2 Select Maintenance… from the Setup menu and press the ENTER button. The Setup
– Maintenance dialog box is displayed.
3 Select Run diag tool.
4 Use the LEFT/RIGHT buttons to select Yes. The Setup – Diag tool dialog box is dis-
played.
5 Select each function/unit and use the LEFT/RIGHT buttons to select Yes/No to include/
exclude the function/unit from the diagnostic test.
NOTE: It is only possible to run a test of a unit if it is powered on.
6 Press the ENTER button to initiate the diagnostic tests.
Press the CANCEL button to exit.