11.4.2.5 Editing autoscan points settings and Moving autoscan points
This section describes how the speed and dwell settings of the autoscan
points are edited and how the position of an autoscan point is moved.
Editing settings and Moving autoscan points
Step Action
1 Do the necessary settings according to section 11.4.2.1.
2 Press the SCN button to enter AUTOSCAN mode.
3 Press the FCN button to enter PROG POSITION mode.
4
Use the
and buttons to go to the desired autoscan point.
5 a To edit the autoscan point, press the FCN button to open the Edit pos # dialog box.
5 b To move the autoscan point, press and hold down the FCN button and use the joystick to
move the system to the new desired position.
Use the JCU to make the desired adjustments of eld-of-view and focus; see section
11.4.2.2.
Press the
FCN button to register and save the position and the eld-of-view, focus and
zoom settings. The Edit pos # dialog box is displayed.
6 Select the Speed and Dwell settings of the autoscan point, see section 11.4.2.3.
7 Repeat step 4-6 to edit next autoscan point or move next autoscan point.
8 Press the CANCEL button to exit the PROG POSITION mode. The Quit programming
dialog box will appear. Select Yes to exit.
9 To save the new autoscan list, see section 11.4.2.7 and section 11.4.2.8.
11.4.2.6 Route sequence
This section describes how the route sequence is managed.
The route sequence denes the order in which the autoscan points shall
be scanned.
The order of the autoscan points in the currently active autoscan list can
be changed and autoscan points can be inactivated. Inactivated autoscan
points are still available and can be activated again if needed.