Ranger HRC™ operator´s manual – Joystick Control Unit
Publ. No. TM 614 006 699 Rev B – ENGLISH (EN) – Oct 30. 2008 37
6.2.2 AUTOSCAN mode
The AUTOSCAN mode is entered by pressing the SCN button in NOR-
MAL or PARK mode. If no autoscan points have been dened, the system
will stay in NORMAL or PARK mode when the SCN button is pressed.)
JCU joystick and keypad – AUTOSCAN mode
Feature Description
Joystick Move the joystick in any direction to enter NORMAL mode.
FCN Press the FCN button to enter PROG POSITION mode.
SCN No function in AUTOSCAN mode.
ID Reserved for future capabilities.
TV/IR Press the TV/IR button to toggle between TV imaging and IR imaging.
INV Press the INV button to toggle between White hot and Black hot IR palette.
C Press the C button to enter NORMAL mode.
NUC Press the NUC button < 1
second
to perform an Internal NUC.
Press the NUC button > 1
second
to perform a one-shot auto focus adjustment.
Press the
FCN + NUC buttons < 1
second
to perform an External NUC against the
lens cover.
Press the FCN + NUC buttons > 1
second
to go to the xed focus position.
Press the
C + NUC buttons < 1
second
to perform an External NUC against the
scene.
Press the C + NUC buttons > 1
second
to perform a one-shot auto focus adjustment.
NOTE: The default behavior (above) of the NUC and FCN + NUC buttons can
be inverted in the
Setup-Image dialog box, see section 7.6.1.1.
PRK Press the PRK button < 1
second
to send the system to the home position. If the
PRK button is pressed < 1
second
again when the system is in home position, the
lens cover of the IR Camera will be closed and PARK mode will be entered, see
section 5.1.3.
Press the
PRK button > 1
second
to send the system to the mechanical home posi-
tion, close the lens cover of the IR Camera and enter PARK mode, see section 5.1.3.
NOTE: At system start up, the PRK button has to be pressed for more than 3
seconds to activate the Pan/Tilt unit.
No function in AUTOSCAN mode.