Ranger HRC™ operator´s manual – System operation
150 Publ. No. TM 614 006 699 Rev B – ENGLISH (EN) – Oct 30. 2008
Storing/recalling/deleting autoscan lists
Step Action
1 Ensure that IR is selected. If not, press the TV/IR button to select IR.
2 Press the ENTER button to enter MENU mode.
3 Select Store/recall… from the Pan/Tilt menu and press the ENTER button. The Store/
recall position list dialog box is displayed.
4 Select the List no item.
5 Use the LEFT/RIGHT button to select the desired list name.
6 Select the Action item.
7 Use the LEFT/RIGHT button to select the desired action.
8 Press the ENTER button to execute the Store, Recall or Delete action.
When storing:
If the list name is already used, the Overwrite list dialog box will be displayed.
Select Yes to overwrite the list and to exit MENU mode.
Select No to return to the Store/recall position list dialog box.
When recalling:
The Overwrite active list dialog box will be displayed.
Select Yes to overwrite the currently active autoscan list and to exit MENU mode.
Select No to return to the Store/recall position list dialog box.
When deleting:
The Delete list dialog box will be displayed and to exit MENU mode.
Select Yes to delete the selected list.
Select No to to the Store/recall position list dialog box.
11.4.2.8 Saving current autoscan list
This section describes how the currently active autoscan list is saved. The
saved list will be available the next time the system is started up.
Saving current autoscan list
Step Action
1 Press the PRK button to save the currently active autoscan list.