3.3 Running Mode
3-6
*1 A value exceeding 9999 cannot be displayed as is on the 4-digit LED monitor screen, so the LED monitor
displays one-tenth of the actual value with the x10 LED lit.
*2 Calculated torque 100% is equal to the motor rated torque. For the calculation formula of the motor rated
torque, refer to E.2 “Calculated formula” (1) in Appendix E “Conversion from SI Units.”
*3 When the LED monitor displays the output voltage, the 7-segment letter
u
in the lowest digit stands for the
unit of the voltage “V.”
*4 When the LED monitor displays the motor output, the unit LED indicator “kW” blinks.
*5 When the LED monitor displays the load factor, the 7-segment letter
;
in the lowest digit stands for “%.”
*6 These PID related items appear only under the PID control specified by function code J01 (= 1, 2 or 3).
*7 When the LED monitor displays a PID command or its output amount, the dot (decimal point) attached to the
lowest digit of the 7-segment letter blinks.
*8 When the LED monitor displays a PID feedback amount, the dot (decimal point) attached to the lowest digit of
the 7-segment letter lights.
*9 The analog input monitor appears only when the analog input monitor function is assigned to one of the
analog input terminals by one of function codes E61 to E63 (= 20). Specify the unit with C58, C64 and C70.
When the displayed value is less than -999, the x10 LED is lit.
*
10
0
appears under the V/f control.
*11 The Timer screen appears only when the timed operation is enabled with function code C21 (C21 = 1).