Appendix G Conformity with Standards
Appendix-26
Appendix G Conformity with Standards
G.1 Compliance with European Standards ( )
The CE marking on Fuji products indicates that they comply with the essential requirements of the Electromagnetic
Compatibility (EMC) Directive 2004/108/EC, Low Voltage Directive 2006/95/EC, and Machinery Directive
2006/42/EC which are issued by the Council of the European Communities.
Table G-1 Conformity with Standards
Standards
EMC Directives
IEC/EN61800-3 : 2004/A12012
Immunity : Second environment (Industrial)
Emission : Category C2 (Applicable only when an optional
EMC-compliant filter is attached)
: Type of FRN0012E2E-4 or below : Category C2
Type of FRN0011E2E-7 or below : Category C2
Type of FRN0020E2E-4 or above : Category C3
(Applicable only to the EMC filter built-in type of
inverters)
IEC/EN61326-3-1 : 2008
Low Voltage Directive IEC/EN61800-5-1 : 2007
CAUTION
The EMC filter built-in type of the FRENIC-Ace inverters is categorized as Category C3of the EN61800-3. It is
not designed for use in a domestic environment. It may interfere with the operations of home appliances or office
equipment due to noise emitted from it.
[ 1 ] Compliance with EMC standards
The CE marking on inverters does not ensure that the entire equipment including our CE-marked products is
compliant with the EMC Directive. Therefore, CE marking for the equipment shall be the responsibility of the
equipment manufacturer. For this reason, Fujis CE mark is indicated under the condition that the product shall be
used within equipment meeting all requirements for the relevant Directives. Instrumentation of such equipment
shall be the responsibility of the equipment manufacturer.
Generally, machinery or equipment includes not only our products but other devices as well. Manufacturers,
therefore, shall design the whole system to be compliant with the relevant Directives.
List of EMC-compliant filters
To satisfy the requirements noted above, use the EMC filter built-in type inverters or the combination of the basic
type of inverters that have no built-in EMC filter and an external filter (option) dedicated to Fuji inverters. In either
case, mount inverters in accordance with the installation procedure given below. To ensure the compliance, it is
recommended to mount the inverters in a metal panel.
Our EMC compliance test is performed under the following conditions.
Wiring length (of the shielded cable) between the inverter (EMC filter built
-in type) and motor: 10m
To use Fuji inverters in combination with a PWM converter, the basic type of inverters having no built-in
EMC filter should be used. Use of an EMC filt
er built-
in type may increase heat of capacitors in the
inverter, resulting in
damage. In addition, the effect of the EMC filter can no longer be expected.