EasyManua.ls Logo

Fuji Electric FRENIC-Ace series - Appendices

Fuji Electric FRENIC-Ace series
788 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
APPENDICES
Contents
Appendix A Trouble-free Use of Inverters (Notes on electrical noise) ······································· 1
A.1
Effect of inverters on other devices ·································································· 1
[ 1 ] Effect on AM radios ······················································································ 1
[ 2 ] Effect on telephones ····················································································· 1
[ 3 ] Effect on proximity switches ··········································································· 1
[ 4 ] Effect on pressure sensors ············································································· 1
[ 5 ] Effect on position detectors (pulse encoders) ····················································· 1
A.2 Noise ········································································································· 2
[ 1 ] Inverter noise ······························································································ 2
[ 2 ] Types of noise ····························································································· 3
A.3 Measures ··································································································· 5
[ 1 ] Noise prevention prior to installation ································································· 5
[ 2 ] Implementation of noise prevention measures ···················································· 5
[ 3 ] Noise prevention examples ············································································ 8
Appendix B
Japanese Guideline for Suppressing Harmonics by Customers Receiving High Voltage or
Special High Voltage (General-purpose inverter)
····················································· 12
B.1
Application to general-purpose inverters ·························································· 12
[ 1 ] Guideline for suppressing harmonics in home electric and
general-purpose appliances ········································································· 12
[ 2 ] Guideline for suppressing harmonics by customers receiving high voltage or
special high voltage ···················································································· 12
B.2 Compliance to the harmonic suppression for customers receiving high voltage or
special high voltage ···················································································· 13
[ 1 ] Calculation of equivalent capacity (Pi)····························································· 13
[ 2 ] Calculation of Harmonic Current ···································································· 14
[ 3 ] Examples of calculation ··············································································· 16
Appendix C Effect on Insulation of General-purpose Motors Driven with 400 V Class Inverters ···· 17
C.1
Generating mechanism of surge voltages ························································ 17
C.2 Effect of surge voltages ··············································································· 18
C.3 Countermeasures against surge voltages ························································ 19
[ 1 ] Using a surge suppressor unit, SSU (Patent pending) ········································ 19

Table of Contents

Related product manuals