11.26 PG interface card (OPC-E2-PG)
11-80
11.26.3 Constraints on standard control circuit terminal
Some control circuit terminals of OPC-E2-PG are different from the terminals of the standard specification of
FRENIC-Ace. Different specifications are as follows.
Table 11.26-3
Item
Specifications
Standard control circuit terminal OPC-E2-PG
FRN□□□□E2■-2/4/7GA FRN□□□□E2■-2/4/7GB,-4C
Power supply “PLC” Power supply for digital input terminals, X1 to X5, FWD
and REV. In addition, it can output 100mA (5V) for
external devices.
Power supply for digital
input terminals only
Degital input “X5”
Available as pulse train input.
Not available as pulse train
input.
Anlog output “FM2” N Y N
CAN-Open Y N N
RS-485 Y Y N
11.26.4 Terminal functions
Table 11.26-4
Function Symbol
Name Specifications
Feedback side
(PG interface)
PO
Power output
to PG
The external device power supply output.
5V power output is possible.
YA A-Phase Input terminal for A-phase pulse train feedback from PG
YB B-Phase Input terminal for B-phase pulse train feedback from PG
YZ Z-Phase Input terminal for Z-phase pulse train feedback from PG
CM common
Power supply common terminal of PG / pulse train / digital
input. It is insulated from the terminal “11”.
PI
External power
input
Power input terminal from the external device for PG.
+5Vdc±10%
Command side
(pulse train
interface)
PO Power output
The external device power supply output.
5V power output is possible.
XA A-Phase Input terminal for A-phase command pulse train
XB B-Phase Input terminal for B-phase command pulse train
XZ - Not used
CM common
Power supply common terminal of PG / pulse train / digital
input. It is insulated from terminal “11”.