2.4 RJ-45 Cover
2-59
INSTALLATION AND WIRING
Chap 2
2.4 RJ-45 Cover
The opening for the RS-485 communication cable connection (RJ-45 connector) is located below the keypad, as
shown in Figure 2.4-1 and Figure 2.4-2. There is not the RJ-45 connector in model GB and C.
Types FRN0069E2-2GA / FRN0044E2-4GA / FRN0011E2-7GA or below
To connect the RS-485 communication cable, open the RJ-45 cover as shown in Figure 2.4-1.
Figure 2.4-1 Connection of the RS-485 Communication Cable
Types FRN0088E2-2GA / FRN0059E2-4GA or above
To connect the RS-485 communication cable, open the RJ-45 cover until the clickcan be heard and connect the
cable, as shown in Figure 2.4-2.
Figure 2.4-2 Connection of the RS-485 Communication Cable
Connect with the PC via the RS-485 converter using the RS-485 communication cable. The PC loader allows
editing, confirmation, and management of the inverter function codes, and monitoring of operation data remotely.
The operating status and alarms can also be monitored.
RJ-45 cover
RJ-45 cover