3.3 Running Mode
3-14
3.3.6 Jogging operation
This section provides the procedure for jogging the motor.
(1) Make the inverter ready to jog by following the steps below. The LED monitor should display
jog
.
Enter Running mode (see “3.2 Overview of Operation Modes” on page 3-3) and press the +
keys
simultaneously.
The LED monitor displays the jogging frequency for approximately one second and then displays
jog
again.
• Function codes C20, H54 and H55 specify the jogging frequency and acceleration/deceleration
time, respectively. Use these function codes exclusively for the jogging operation with your
Alternatively, using the input terminal command JOG (“Ready for jogging”)
normal operation state and ready-to-jog state.
Switching between the normal operation state and read-to-jog state with the +
possible only when the inverter is stopped.
(2) Jogging the motor.
Hold down the key during which the motor continues jogging. To decelerate to stop the motor, release the
key.
(3) Exiting the ready-to-jog state and returning to the normal operation state.
Press the
+
keys simultaneously.
For details, refer to the descriptions of function codes E01 to E05 in Chapter 5 “5.2.2 Function codes table.”