11.9 Power Regenerative PWM Converters, RHC Series
11-37
SELECTING PERIPHERAL EQUIPMENT
Chap 11
Communications specifications
Item
Specifications
General communication
specifications
Monitoring the running information, running status and function code data, and controlling
(selecting) the terminals [RUN], [RST] and [X1].
* Writing to function codes is not possible.
RS-485 (standard)
Communicating with a PC or PLC.
(The converter supports the Fuji general-purpose inverter protocol and Modbus RTU
protocol.)
T-Link (option)
Mounting the OPC-VG7-TL option enables communication with a T-Link module of
MICREX-F or MICREX-SX via a T-Link network.
SX-bus (option)
Mounting the OPC-VG7-SX option enables communication with a MICREX-SX via an SX
bus network.
CC-Link (option)
Mounting the OPC-VG7-CCL option enables communication with a CC-Link master.
Traceback (option)
Hardware
Mounting the OPC-RHC-TR option enables tracing back of the running status data of the
converter.
WPS-LD-TR software is required.
Software
Installing the WPS-RHC-TR software enables collecting of traceback data on the PC.
Function settings
Function code
Name
F00
Data protection
F01
High frequency filter selection
F02
Restart mode after momentary power failure (Mode selection)
F03
Current rating switching
F04
LED monitor, item selection
F05
LCD monitor, item selection
F06
LCD monitor, language selection
F07
LCD monitor, contrast control
F08
Carrier frequency
E01
Terminal [X1] function
E02 to E13
Terminal [Y1], [Y2], [Y3,], [Y5], [Y11] to [Y18] function
E14
I/O function normal open/closed
E15
RHC overload early warning level
E16
Cooling fan ON/OFF control
E17
Under current limiting (Hysteresis width)
E18 to E20
A01, A04 and A05, function selection
E21 to E23
A01, A04 and A05, gain setting
E24 to E26
A01, A04 and A05, bias setting
E27
A01, A04 and A05, filter setting
S01
Operation method
S02, S03
Power supply current limiting (driving/braking)
H01
Station address
H02
Communications error processing
H03
Timer
H04
Baud rate
H05
Data length
H06
Parity bits
H07
Stop bits
H08
No-response error detection time
H09
Response interval
H10
Protocol selection
H11
TL transmission format
H12
Parallel system
H13
Number of slave stations in parallel system
H14
Clear alarm data
H15, H16
Power supply current limiter (driving 1/2)
H17, H18
Power supply current limiter (braking 1/2)
H19, H20
Current limiting early warning (level/timer)
M09
Power supply frequency
M10
Input power
M11
Input current in RMS
M12
Input voltage in RMS
M13
Run command
M14
Running status
M15
Output terminals [Y1] to [Y18]