EasyManua.ls Logo

Fuji Electric FRENIC-Ace series - Page 431

Fuji Electric FRENIC-Ace series
788 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5.3 Description of Function Codes
5-261
FUNCTION CODES
Chap 5
The block diagrams for each operation function block are given below. The setting value for functions 1 and 2 is
indicated with U04 and U05.
(2001) Adder
Output
Input 1
Input 2
+
+
U04
U05
(2002) Subtracter
Output
Input 1
Input 2
-
+
U04
U05
(2003) Multiplier
Output
Input 1
Input 2
U04
U05
×
(2004) Divider
Output
Input 1
Input 2
U04
U05
÷
(2005) Limiter
Output
Input 1
Input 2
U04
U05
(2006) Absolute value of inputs
Output
Input 1
Input 2
Absolute
value
Operation
U04
U05
(2007) Inverting adder
Output
Input 1
Input 2
+
U04 -1
×
U05
+
+
(2009) Linear function
(2051) Comparator 1
Output
Input 1
Input 2
With Input 1-Input 2 U04+|U05|
Output ON
With Input 1-Input 2 U04-|U05|
Output OFF
(2052) Comparator 2
Output
Input 1
Input 2
With Input 1-Input 2 > U04+|U05|
Output ON
With Input 1-Input 2 < U04-|U05|
Output OFF
ON is prioritized when both conditions are satisfied.
(2053) Comparator 3
Output
Input 1
Input 2
|With Input 1-Input 2| U04+|U05|
Output ON
|With Input 1-Input 2| ≤ U04-|U05|
Output OFF
(2054) Comparator 4
(2055) Comparator 5
Output
Input 1
Output ON when Input 1 ≥ U04
Output OFF when Input 1 < U04 – |U05|
U04
ON is prioritized when both conditions are satisfied.
Out
In
1
In
2
KA×入力1+KB
U04 U05
Input 1
Input 2
Output
Input 1
Input 2
Output
|With Input 1-Input 2| < U04-|U05|
Output OFF
|With Input 1-Input 2| > U04+|U05|
Output ON

Table of Contents