5.3 Description of Function Codes
5-261
FUNCTION CODES
Chap 5
The block diagrams for each operation function block are given below. The setting value for functions 1 and 2 is
indicated with U04 and U05.
Output
Input 1
Input 2
+
+
U04
U05
Output
Input 1
Input 2
-
+
U04
U05
Output
Input 1
Input 2
U04
U05
×
Output
Input 1
Input 2
U04
U05
÷
Output
Input 1
Input 2
U04
U05
(2006) Absolute value of inputs
Output
Input 1
Input 2
Absolute
value
Operation
U04
U05
Output
Input 1
Input 2
+
‒
U04 -1
×
U05
+
+
Output
Input 1
Input 2
With Input 1-Input 2 ≥ U04+|U05|
Output ON
With Input 1-Input 2 ≤ U04-|U05|
Output OFF
Output
Input 1
Input 2
With Input 1-Input 2 > U04+|U05|
Output ON
With Input 1-Input 2 < U04-|U05|
Output OFF
ON is prioritized when both conditions are satisfied.
Output
Input 1
Input 2
|With Input 1-Input 2| ≥ U04+|U05|
Output ON
|With Input 1-Input 2| ≤ U04-|U05|
Output OFF
Output
Input 1
Output ON when Input 1 ≥ U04
Output OFF when Input 1 < U04 – |U05|
U04
ON is prioritized when both conditions are satisfied.
Out
In
1
In
2
KA×入力1+KB
U04 U05
|With Input 1-Input 2| < U04-|U05|
Output OFF
|With Input 1-Input 2| > U04+|U05|
Output ON