EasyManua.ls Logo

Fuji Electric FRENIC-Ace series - Page 451

Fuji Electric FRENIC-Ace series
788 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5.3 Description of Function Codes
5-281
FUNCTION CODES
Chap 5
y99
Loader link function (Mode selection)
Function code to switch the links to the inverter supporting loader software (FRENIC Loader). Rewriting y99 with
the inverter supporting loader software (FRENIC Loader) enables the frequency command and operation
command from the inverter supporting loader software (FRENIC Loader). You do not need to use the keypad since
the data is rewritten from the inverter supporting loader.
If the operation command is configured to be given from the inverter supporting loader software, and if the
computer starts to go out of control during the operation and a stop command from the loader software is ignored,
remove the communication cable connected to the computer that runs the inverter supporting loader software, and
connect the keypad to set the y99 data to 0. By setting the y99 data to 0, the operation is isolated from the inverter
supporting loader software's commands, switching to the commands of inverter's own settings (such as function
code H30).
The y99 data is not saved in the inverter; the setting is lost and returned to 0 when powered off.
y99 data
Function
Frequency command Run command source
0 From function codes H30 and y98 From function codes H30 and y98
1 Command issued from FRENIC loader From function codes H30 and y98
2 From function codes H30 and y98 Command issued from FRENIC loader
3 Command issued from FRENIC loader Command issued from FRENIC loader

Table of Contents

Related product manuals