9.2 CANopen Communication
9-49
COMMUNICATION FUNCTIONS
Chap 9
9.2.15 Keypad LED operation monitor
3_40
The status of CAN communication is displayed in the LED operation monitor item
3_40
in the keypad.
Display item CANopen state LED Display Data
3_40
No-operation state (no operation is selected)
0
Stopstate
1
“Pre-Operationalstate
2
Operationalstate
3
9.2.16 Keypad LED operation monitor
3_41
The status of CAN bus is displayed in the LED operation monitoring item
3_41
in the keypad.
Monitored Value CAN bus Status
0 Normal
1 Error passive
2 Bus off
9.2.17 Keypad LED operation monitor
3_42
The transition state of the state machine defined in the DSP-402 is displayed in the LED operation monitoring item
3_42
in the keypad.
9.2.18 Keypad LED maintenance information
5_45
The sending error counter during communication is displayed in the LED maintenance Information item
5_45
in
the keypad.
9.2.19 Keypad LED maintenance information
5_46
The receiving error counter during communication is displayed in the LED maintenance Information item
5_46
in the keypad.
Monitored Value Status of the DSP-402 state machine Inverter state
0 Invalid y33=0
1 Not ready to switch on Refer to Table 9.2-18.
2 Switch on disabled
3 Ready to switch on
4 Switched on
5 Operation enabled
6 Quick stop active
7 Fault reaction active
8 Fault