Severity Level 6
Error Message Error accessing dot1x config data for interface <Interface
Number> in dot1xIntfIsConfigurable.
Explanation There is synchronization issue between NIM and components
w.r.t. interface creation/deletion.
Recommended Action The dot1x system is crashed.
Severity Level 6
Error Message dot1xLocalAuthMd5ResponseValidate: couldn't allocate
responseData
Explanation Couldn't allocate memory for MD5 challenge response
validation.
Recommended Action MD5 messages is invalid.
Severity Level 6
Error Message dot1xRadiusAcceptProcess: EAP message not received from
server
Explanation EAP message not received from radius server.
Recommended Action The system is disconnected by the Radius Server.
Severity Level 6
Error Message dot1xRadiusAcceptProcess: error calling radiusAccountingStart,
ifIndex=<Interface Number>
Explanation The port was previously unauthorized and send accounting start
to server failed.
Recommended Action The Radius Process is abnormal.
Severity Level 6
Error Message dot1xRadiusChallengeProcess: Out of System buffers
Explanation Out of system buffer while process RADIUS challenge from
server.
Recommended Action The Radius Process is out of system memory.
Severity Level 6
Error Message dot1xRadiusAccountingStart: error calling
radiusAccountingStart, ifIndex=<Interface Index>
Explanation The port was previously unauthorized and send accounting start
to server failed.
Recommended Action The port setting is not available for the dot1x module.